Duo Photometer plus

 

Duo Photometer plus

Duo Photometer plus

Booklet Duo Photometer plus DP 350

Adobe Acrobat Reader DC Install now
Download PDF
 

Duo Photometer plus DP 350

One measuring device for the key parameters

The Duo Photometer plus can measure the most frequently applied parameters.Itisthereforeareliablepartnerinvariousareas:

  • In many gynaecology practices for measuring haemoglobin and glucose in prenatal care.
  • As a companion for midwives, as it saves new mothers a visit to the doctor by measuring neonatal bilirubin at home.
  • Lactate plays an important role in performance diagnostics, rehabilitation sports and emergency diagnostics. The device can record it in a few minutes and up to 20 samples can be measured at the same time.

The device, together with the accessories and the mini centrifuge, can be stored in an equipment case.

Duo Photometer plus DP 350
Size/Weight: 19x10x5 cm/0,4 kg
Wavelength: 520/546 nm
Mains or battery (9V) – operated
Photometric inaccuracy: < 0.5 % at A=1.000


Mini centrifuge DZ 002
Diameter / Weight: 16 cm /1 kg


Equipment case DK 002
Size / Weight: 45 × 36 × 14 cm / 1,6 kg

Sample material Accessories
Parameter Art. No. Sample volume Capillary/Venous blood Serum Plasma Mini centrifuge
Bilirubin BIL 142 100 μL * *
Bilirubin Neonatal1 BIL 142 20 μL * * * *
Erythrocytes ERY 142 10 μL *
Glucose GLU 142 10 μL * * *
Haemoglobin-HiCN HB 142 10 μL *
Haemoglobin-SLS HB 342 10 μL *
Haematokrit HCT 142 10 μL *
Lactat LAC 142 10 μL * *
1 1 Approx.100µL of capillary blood and the mini centrifuge are required to obtain 20µL of serum/plasma.

Duo Photometer plus DP 350

Art. No. Description
DP 350 Duo Photometer plus incl. Power supply and instructions

Accessories

Art. No. Description
DK 002 Gerätekoffer
DZ 002 Minizentrifuge
LH 006 Küvettenständer
LH 007 Mikropipetter (Pipettierhilfe)

Test kit

Art. No. Description Content
BIL 142 Bilirubin, Bilirubin neonatal 40 Tests
ERY 142 Erythrocyten 40 Tests
GLU 142 Glucose 40 Tests
HCT 142 Hämatokrit 40 Tests
HB 142 Hämoglobin-HiCN 40 Tests
HB 342 Hämoglobin-SLS 40 Tests
LAC 142 Lactat 40 Tests

Consumables

Art. No. Description Content
LH 026 Kapillaren, 10 µL, Ringmarke 250
LH 029 Kapillaren, 20 µL, Ringmarke 250
LH 028 Kapillaren, 100 µL, Ringmarke 250
LH 037 Microvetten, 200µL, Li-Hep. 100

Control materials

Art. No. Description Content
HEM QS Richtigkeits- und Präzisionskontrolle der Hämoglobin-Bestimmung 5 x 1mL
ERY QS Richtigkeits- und Präzisionskontrolle der ERY- und HCT-Bestimmung 5 x 1mL
LAC QS Lactat-Kontrollset, 2,00 / 4,00 / 10,0 mmol/L 3 x 4mL
GLU QS Richtigkeits- und Präzisionskontrolle der Glucose-Bestimmung 3 x 4mL
BIL QS Richtigkeits- und Präzisionskontrolle der Bilirubin-Bestimmung 20 Tests