Duo Photometer plus DP 350
One measuring device for the key parameters
The Duo Photometer plus can measure the most frequently applied parameters.Itisthereforeareliablepartnerinvariousareas:
- In many gynaecology practices for measuring haemoglobin and glucose in prenatal care.
- As a companion for midwives, as it saves new mothers a visit to the doctor by measuring neonatal bilirubin at home.
- Lactate plays an important role in performance diagnostics, rehabilitation sports and emergency diagnostics. The device can record it in a few minutes and up to 20 samples can be measured at the same time.
The device, together with the accessories and the mini centrifuge, can be stored in an equipment case.
Duo Photometer plus DP 350
Size/Weight: 19x10x5 cm/0,4 kg
Wavelength: 520/546 nm
Mains or battery (9V) – operated
Photometric inaccuracy: < 0.5 % at A=1.000
Mini centrifuge DZ 002
Diameter / Weight: 16 cm /1 kg
Equipment case DK 002
Size / Weight: 45 × 36 × 14 cm / 1,6 kg
Size/Weight: 19x10x5 cm/0,4 kg
Wavelength: 520/546 nm
Mains or battery (9V) – operated
Photometric inaccuracy: < 0.5 % at A=1.000
Mini centrifuge DZ 002
Diameter / Weight: 16 cm /1 kg
Equipment case DK 002
Size / Weight: 45 × 36 × 14 cm / 1,6 kg
Sample material | Accessories | |||||
---|---|---|---|---|---|---|
Parameter | Art. No. | Sample volume | Capillary/Venous blood | Serum | Plasma | Mini centrifuge |
Bilirubin | BIL 142 | 100 μL | * | * | ||
Bilirubin Neonatal1 | BIL 142 | 20 μL | * | * | * | * |
Erythrocytes | ERY 142 | 10 μL | * | |||
Glucose | GLU 142 | 10 μL | * | * | * | |
Haemoglobin-HiCN | HB 142 | 10 μL | * | |||
Haemoglobin-SLS | HB 342 | 10 μL | * | |||
Haematokrit | HCT 142 | 10 μL | * | |||
Lactat | LAC 142 | 10 μL | * | * | ||
1 1 Approx.100µL of capillary blood and the mini centrifuge are required to obtain 20µL of serum/plasma. |
Duo Photometer plus DP 350
Art. No. | Description |
---|---|
DP 350 | Duo Photometer plus incl. Power supply and instructions |
Accessories
Art. No. | Description |
---|---|
DK 002 | Gerätekoffer |
DZ 002 | Minizentrifuge |
LH 006 | Küvettenständer |
LH 007 | Mikropipetter (Pipettierhilfe) |
Test kit
Art. No. | Description | Content |
---|---|---|
BIL 142 | Bilirubin, Bilirubin neonatal | 40 Tests |
ERY 142 | Erythrocyten | 40 Tests |
GLU 142 | Glucose | 40 Tests |
HCT 142 | Hämatokrit | 40 Tests |
HB 142 | Hämoglobin-HiCN | 40 Tests |
HB 342 | Hämoglobin-SLS | 40 Tests |
LAC 142 | Lactat | 40 Tests |
Consumables
Art. No. | Description | Content |
---|---|---|
LH 026 | Kapillaren, 10 µL, Ringmarke | 250 |
LH 029 | Kapillaren, 20 µL, Ringmarke | 250 |
LH 028 | Kapillaren, 100 µL, Ringmarke | 250 |
LH 037 | Microvetten, 200µL, Li-Hep. | 100 |
Control materials
Art. No. | Description | Content |
---|---|---|
HEM QS | Richtigkeits- und Präzisionskontrolle der Hämoglobin-Bestimmung | 5 x 1mL |
ERY QS | Richtigkeits- und Präzisionskontrolle der ERY- und HCT-Bestimmung | 5 x 1mL |
LAC QS | Lactat-Kontrollset, 2,00 / 4,00 / 10,0 mmol/L | 3 x 4mL |
GLU QS | Richtigkeits- und Präzisionskontrolle der Glucose-Bestimmung | 3 x 4mL |
BIL QS | Richtigkeits- und Präzisionskontrolle der Bilirubin-Bestimmung | 20 Tests |